Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Angiology ; : 33197241226863, 2024 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-38185884

RESUMEN

Female gender is a risk factor in several cardiac surgery risk stratification systems. This study explored the differences in the outcomes following triple heart valve surgery in men vs women. The study included 250 patients (males n = 101; females n = 149) who underwent triple valve surgery from 2009 to 2020. BMI (body mass index) was higher in females (29.6 vs 26.5 kg/m2, P < .001), and diabetes was more common in males (44 vs 42%, P = .012). The ejection fraction was higher in females (55 vs 50%, P < .001). The severity of mitral valve stenosis and tricuspid valve regurgitation was significantly greater in females (33.11 vs 27.72%, P = .003 and 44.30 vs 19.8%, P < .001, respectively). Mitral valve replacement was more common in females (P < .001), and they had lower concomitant coronary artery bypass grafting (P = .001). Bleeding and renal failure were lower in females (P = .021 and <0.001, respectively). Hospital mortality, readmission, and reintervention were not significantly different between genders. By multivariable analysis, male gender was a risk factor for lower survival [HR (hazard ratio): 2.18; P = .024]. Triple valve surgery can be performed safely in both genders, with better long-term survival in females. Female gender was not a risk factor in patients undergoing triple valve surgery.

2.
Perfusion ; 39(3): 564-570, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36645201

RESUMEN

BACKGROUND: Limited data evaluated the outcomes of extracorporeal membrane oxygenation (ECMO) in patients with prosthetic valves. This study aimed to compare the outcomes of ECMO support for postcardiotomy cardiogenic shock in patients with mechanical versus bioprosthetic valves. METHODS: This retrospective study included patients with ECMO support for postcardiotomy cardiogenic shock after valve replacement. Patients were grouped into bioprosthetic (n = 49) and mechanical valve (n = 22) groups. RESULTS: There were no differences in ECMO duration, inotropic support, intra-aortic balloon pump (IABP), stroke, duration of ICU, and hospital stay between groups. Postoperative thrombosis occurred in 2 patients with bioprosthetic valves (5.41%) and 2 with mechanical valves (14.29%), p = .30. All patients with thrombosis had central ECMO cannulation, concomitant IABP, and inotropic support during ECMO. All thrombi were related to the mitral valve. Three patients with thrombi had hospital mortality.Survival at 6, 12, and 36 months for bioprosthetic valve patients was 30.88%, 28.55%, and 25.34% and for mechanical valves was 36.36% for all time intervals (Log-rank p = .93). One patient had bioprosthetic aortic valve endocarditis after 1 year. Three patients with bioprosthetic valves had structural valve degeneration after 1, 2, and 5 years. CONCLUSIONS: Outcomes of ECMO in patients with prosthetic valves are comparable between bioprosthetic and mechanical valves. Thrombosis might occur in both valve types and was associated with high mortality. ECMO could affect the long-term durability of the bioprosthetic valves.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Accidente Cerebrovascular , Trombosis , Humanos , Choque Cardiogénico/etiología , Choque Cardiogénico/cirugía , Oxigenación por Membrana Extracorpórea/efectos adversos , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Trombosis/etiología
3.
Angiology ; 75(4): 331-339, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36710003

RESUMEN

There is no consensus regarding mitral valve management during surgical ventricular restoration (SVR) for ischemic cardiomyopathy. We compared the impact of SVR with mitral valve repair (MVr) vs replacement (MVR) on postoperative outcomes and long-term survival in ischemic cardiomyopathy and mitral regurgitation patients. This study included 112 patients who underwent SVR from 2009 to 2018 with MVr (n = 75) or MVR (n = 37). Patients who had MVR had higher Euro SCORE II, dyspnea class, a lower ejection fraction, higher pulmonary artery systolic pressure, higher grade of preoperative mitral and tricuspid regurgitation, and higher end-diastolic and end-systolic diameters. Intra-aortic balloon pump was more commonly used in patients with MVR. Hospital mortality occurred in 7 (9.33%) patients in the MVr group vs 3 (8.11%) in the MVR group (P > .99). Freedom from rehospitalization at 1, 5, and 7 years was 87%, 76%, and 70% in the MVr group and 83%, 61%, and 52% in the MVR group (P = .191). Survival at 1, 5, and 7 years was 88%, 78%, and 74% in the MVr group and 88%, 56%, and 56% in the MVR group (P = .027). Adjusted survival did not differ between groups.MVr or MVR are valid options in patients undergoing SVR, with good long-term outcomes.


Asunto(s)
Cardiomiopatías , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Isquemia Miocárdica , Humanos , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Cardiomiopatías/cirugía
4.
Braz J Cardiovasc Surg ; 38(5): e20230013, 2023 08 04.
Artículo en Inglés | MEDLINE | ID: mdl-37540779

RESUMEN

INTRODUCTION: We studied the effect of tricuspid valve (TV) surgery combined with surgical ventricular restoration (SVR) on operative outcomes, rehospitalization, recurrent tricuspid regurgitation, and survival of patients with ischemic cardiomyopathy. Additionally, surgery was compared to conservative management in patients with mild or moderate tricuspid regurgitation. To the best of our knowledge, the advantage of combining TV surgery with SVR in patients with ischemic cardiomyopathy had not been investigated before. METHODS: This retrospective cohort study included 137 SVR patients who were recruited from 2009 to 2020. Patients were divided into two groups - those with no concomitant TV surgery (n=74) and those with concomitant TV repair or replacement (n=63). RESULTS: Extracorporeal membrane oxygenation use was higher in SVR patients without TV surgery (P=0.015). Re-exploration and blood transfusion were significantly higher in those with TV surgery (P=0.048 and P=0.037, respectively). Hospital mortality occurred in eight (10.81%) patients with no TV surgery vs. five (7.94%) in the TV surgery group (P=0.771). Neither rehospitalization (log-rank P=0.749) nor survival (log-rank P=0.515) differed in patients with mild and moderate tricuspid regurgitation in both groups. Freedom from recurrent tricuspid regurgitation was non-significantly higher in mild and moderate tricuspid regurgitation patients with no TV surgery (P=0.059). Conservative management predicted the recurrence of tricuspid regurgitation. CONCLUSION: TV surgery concomitant with SVR could reduce the recurrence of tricuspid regurgitation; however, its effect on the clinical outcomes of rehospitalization and survival was not evident. The same effects were observed in patients with mild and moderate tricuspid regurgitation.


Asunto(s)
Cardiomiopatías , Implantación de Prótesis de Válvulas Cardíacas , Isquemia Miocárdica , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Factores de Riesgo , Factores de Tiempo , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/cirugía , Cardiomiopatías/cirugía
5.
Asian Cardiovasc Thorac Ann ; 31(5): 413-420, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37192641

RESUMEN

BACKGROUND: Tricuspid valve repair (TVr) is the recommended approach for managing tricuspid regurgitation; however, there is a concern about the long-term durability of the repair. Therefore, this study aimed to compare the long-term outcomes of TVr versus tricuspid valve replacement (TVR) in a matched cohort of patients. METHODS: This study included 1161 patients who underwent tricuspid valve (TV) surgery from 2009 to 2020. Patients were grouped according to the procedure into two groups: patients who underwent TVr (n = 1020) and patients who underwent TVR (n = 159). The propensity score identified 135 matched pairs. RESULTS: Renal replacement therapy and bleeding were significantly higher in the TVR group compared to the TVr group both before and after matching. Thirty-day mortality occurred in 38 (3.79%) patients in TVr group versus 3 (1.89%) in the TVR group (P ≤ 0.001) but was not significant after matching. After matching, TV reintervention (hazard ratio (HR): 21.44 (95% CI: 2.17-211.95); P = 0.009) and heart failure rehospitalization (HR: 1.89 (95% CI: 1.13-3.16); P = 0.015) were significantly higher in the TVR group. There was no difference in mortality in the matched cohort (HR: 1.63 (95% CI: 0.72-3.70); P = 0.25). CONCLUSIONS: TVr was associated with lower renal impairment, reintervention, and heart failure rehospitalization than replacement. TVr remains the preferred approach whenever feasible.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Puntaje de Propensión , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia Cardíaca/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
6.
Int J Artif Organs ; 46(6): 384-389, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37125784

RESUMEN

We aimed to compare the outcomes of ECMO with and without IABP for postcardiotomy cardiogenic shock. The study included 103 patients who needed ECMO for postcardiotomy cardiogenic shock. Patients were grouped according to the use of IABP into ECMO without IABP (n = 43) and ECMO with IABP (n = 60). The study endpoints were hospital complications, successful weaning, and survival. Patients with IABP had lower preoperative ejection fraction (p = 0.002). There was no difference in stroke (p = 0.97), limb ischemic (p = 0.32), and duration of ICU stay (p = 0.11) between groups. Successful weaning was non-significantly higher with IABP (36 (60%) vs 19 (44.19%); p = 0.11). Predictors of successful weaning were inversely related to the high pre-ECMO lactate levels (OR: 0.89; p = 0.01), active endocarditis (OR: 0.06; p = 0.02), older age (OR: 0.95; p = 0.02), and aortic valve replacement (OR: 0.26; p = 0.04). There was no difference in survival between groups (p = 0.80). Our study did not support the routine use of IABP during ECMO support.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Corazón Auxiliar , Humanos , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Oxigenación por Membrana Extracorpórea/efectos adversos , Contrapulsador Intraaórtico/efectos adversos , Corazón Auxiliar/efectos adversos , Válvula Aórtica , Estudios Retrospectivos
7.
Perfusion ; 38(7): 1444-1452, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-35841146

RESUMEN

BACKGROUND: The optimal venoarterial extracorporeal membrane oxygenation (VA ECMO) cannulation strategy in patients with postcardiotomy cardiogenic shock is still debatable. Studies evaluating the effect of cannulation strategy on long-term survival are scarce. OBJECTIVES: We investigated the impact of central versus peripheral cannulation strategy for ECMO insertion on hospital outcomes and survival in postcardiotomy cardiogenic shock patients. METHODS: This retrospective study involved 101 patients who had either central or peripheral ECMO due to postcardiotomy shock between June 2009 and December 2020. Study endpoints were limb ischemia, bleeding, blood transfusion, wound infection, and overall survival. RESULTS: Eighty-four patients received central (c) ECMO, and 17 patients had peripheral (p) ECMO. In the group of pECMO, limb ischemia was significantly higher (5 [29.41%] vs 6 [7.14%]; p = .01). Other endpoints were similar in both groups. Thirty-day mortality was nonsignificantly different between both cohorts (cECMO 34 [41.67%] vs pECMO 10 [58.82%]; p = .29). However, overall survival was better with cECMO (Log-rank p = .02). Patients' age [HR: 1.04 (95% CI: 1.02-1.06); p = .001], pECMO [HR: 1.98 (95% CI: 1.11-3.55), p = .002] and presence of infective endocarditis [HR: 3.54 (95% CI: 1.52-8.24), p = .03] were significant predictors of overall mortality. CONCLUSIONS: Peripheral ECMO was associated with an increased risk of limb ischemia; however, bleeding, blood transfusion, infection, and 30-day mortality were comparable to central ECMO. Central cannulation was associated with a better 1-year survival rate. Therefore, central cannulation might be the preferred strategy for patients with postcardiotomy cardiogenic shock.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Choque Cardiogénico , Humanos , Choque Cardiogénico/etiología , Choque Cardiogénico/cirugía , Oxigenación por Membrana Extracorpórea/efectos adversos , Estudios Retrospectivos , Cateterismo , Isquemia/etiología , Hemorragia/etiología
8.
Angiology ; 74(7): 664-671, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35968605

RESUMEN

Currently, there is no preference for surgical (SAVR) vs transcatheter (TAVR) aortic valve replacement in patients with low ejection fraction (EF). The present study retrospectively compared the outcomes of SAVR vs TAVR in patients with EF ≤40% (70 SAVR and 117 TAVR patients). Study outcomes were survival and the composite endpoint of stroke, aortic valve reintervention, and heart failure readmission. The patients who had TAVR were older (median: 75 (25-75th percentiles: 69-81) vs 51 (39-66) years old; P < .001) with higher EuroSCORE II (4.95 (2.99-9.85) vs 2 (1.5-3.25); P < .001). Postoperative renal impairment was more common with SAVR (8 (12.5%) vs 4 (3.42%); P = .03), and they had longer hospital stay [9 (7-15) vs 4 (2-8) days; P < .001). There was no difference between groups in stroke, reintervention, and readmission (Sub-distributional Hazard ratio: .95 (.37-2.45); P = .92). Survival at 1 and 5 years was 95% and 91% with SAVR and 89% and 63% with TAVR. Adjusted survival was comparable between groups. EF improved significantly (ß: .28 (.23-.33); P < 0.001) with no difference between groups (P = .85). In conclusion, TAVR could be as safe as SAVR in patients with low EF.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Adulto , Persona de Mediana Edad , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Volumen Sistólico , Válvula Aórtica/cirugía , Accidente Cerebrovascular/cirugía , Resultado del Tratamiento , Factores de Riesgo
9.
Rev. bras. cir. cardiovasc ; 38(5): e20230013, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1449576

RESUMEN

ABSTRACT Introduction: We studied the effect of tricuspid valve (TV) surgery combined with surgical ventricular restoration (SVR) on operative outcomes, rehospitalization, recurrent tricuspid regurgitation, and survival of patients with ischemic cardiomyopathy. Additionally, surgery was compared to conservative management in patients with mild or moderate tricuspid regurgitation. To the best of our knowledge, the advantage of combining TV surgery with SVR in patients with ischemic cardiomyopathy had not been investigated before. Methods: This retrospective cohort study included 137 SVR patients who were recruited from 2009 to 2020. Patients were divided into two groups - those with no concomitant TV surgery (n=74) and those with concomitant TV repair or replacement (n=63). Results: Extracorporeal membrane oxygenation use was higher in SVR patients without TV surgery (P=0.015). Re-exploration and blood transfusion were significantly higher in those with TV surgery (P=0.048 and P=0.037, respectively). Hospital mortality occurred in eight (10.81%) patients with no TV surgery vs. five (7.94%) in the TV surgery group (P=0.771). Neither rehospitalization (log-rank P=0.749) nor survival (log-rank P=0.515) differed in patients with mild and moderate tricuspid regurgitation in both groups. Freedom from recurrent tricuspid regurgitation was non-significantly higher in mild and moderate tricuspid regurgitation patients with no TV surgery (P=0.059). Conservative management predicted the recurrence of tricuspid regurgitation. Conclusion: TV surgery concomitant with SVR could reduce the recurrence of tricuspid regurgitation; however, its effect on the clinical outcomes of rehospitalization and survival was not evident. The same effects were observed in patients with mild and moderate tricuspid regurgitation.

10.
J Card Surg ; 37(4): 739-746, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35060198

RESUMEN

BACKGROUND: The influence of the etiology of mitral valve (MV) lesion on outcomes of concomitant repair for functional tricuspid regurgitation (TR) is not well studied. Our objectives were to compare long-term survival and TR recurrence after tricuspid valve (TV) repair concomitant with surgery for rheumatic versus degenerative MV disease. METHODS: We included 480 patients who had concomitant MV and TV surgery from 2009 to 2019. We grouped the patients into Group 1 (n = 345; rheumatic MV) and Group 2 (n = 135; degenerative MV). Propensity score matching identified 104 matched pairs. RESULTS: There was no significant difference in survival between groups before (p = .46) or after matching (p = .09). There was no difference in the recurrence of moderate TR (subdistributional hazard ratio [SHR]: 1.22 [0.77-1.95], p = .40). Recurrent TR was significantly associated with the preoperative TR grade (SHR: 1.8 [1.5-2.16], p < .001); body mass index (SHR: 1.05 [1.03-1.08], p < .001), and the use of flexible versus rigid TV prosthesis (SHR: 0.64 [0.41-0.99], p = .042). Recurrence of TR was higher with MV replacement compared with repair (SHR: 1.69 [1.03-2.78], p = .038). The change in the degree of TR did not differ between groups before matching (OR: 0.77 [0.56-1.04], p = .09) or after matching (OR: 0.98 [0.67-1.44]; p = .93). CONCLUSION: Outcomes of concomitant TR repair were comparable in rheumatic and degenerative mitral pathology. Type of the TV prosthesis and TR grade affected TR recurrence. MV repair could be associated with a lower recurrence of TR compared with replacement.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología
11.
Monaldi Arch Chest Dis ; 92(2)2021 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-34865460

RESUMEN

Stuck valve is a very rare and severe complication that occurs in mechanical valve replacement patients with ineffective anticoagulation. However, with COVID-19 restriction measures, it became challenging to regularly assess INR to make sure it falls within the target therapeutic range to prevent this complication. We present a series of 10 patients who either underwent transthoracic echocardiography for a suspected stuck valve or were seen at the outpatient valve clinic with the residual consequences of a stuck valve during the COVID-19 restriction measures in our institute. Stuck prosthetic valves incident has increased significantly during this period, particularly those in the mitral position for which urgent replacement and prolonged hospitalization were necessary. Particularly with the COVID-19 restrictions in place, these cases highlight the need for physicians to be aware of the dramatic increase in the incidence of stuck prosthetic valves in patients on chronic warfarin therapy.


Asunto(s)
COVID-19 , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anticoagulantes/uso terapéutico , Ecocardiografía , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Incidencia
12.
J Card Surg ; 36(6): 1904-1909, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33625788

RESUMEN

BACKGROUND: The number of MtraClip procedures is increasing, and consequently, the number of patients with residual or recurrent mitral regurgitation (MR). We aimed to characterize patients who had residual versus recurrent MR after MitraClip and report the outcomes of different treatment strategies. METHODS: From 2012 to 2020, 167 patients had MitraClip. Out of them, 16 patients (9.5%) had residual mitral regurgitation (MR), and 27 patients (16.2%) had recurrent MR. RESULTS: The median age in patients with residual MR was 67.5 (59-73) years versus 69 (61-78) years in patients with recurrent MR (p = .87). The etiology of mitral valve disease was functional in 13 patients (81.3%) and 22 patients (84.6%) in residual versus recurrent MR patients (p > .99). Cardiac resynchronization therapy-defibrillator implantation was higher in patients with residual MR (p = .02). Survival was 93.7% at 1 year, 76.4% at 3 years versus 92.5% at 1 year, and 84.5% at 3 years in residual versus recurrent MR (p = .69). Two patients in the residual MR group had re-clip, and three had surgery, and in the recurrent MR group, one patient had re-clip, and two patients had surgery (p = .23). Patients who had re-clip were older (p = .09). Surgery was associated with 100% survival at 5 years, 63% after medical therapy and the worst survival was reported in re-clip patients (p = .007). CONCLUSION: The outcomes of patients with residual versus recurrent mitral regurgitation after MitraClip were comparable. Survival could be improved with surgery compared with medical therapy and re-clip.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Cateterismo Cardíaco , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
13.
Rev. bras. cir. cardiovasc ; 36(1): 10-17, Jan.-Feb. 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1155793

RESUMEN

Abstract Introduction: There are scarce data comparing different mechanical valves in the aortic position. The objective of this study was to compare the early hemodynamic changes after aortic valve replacement between ATS, Bicarbon, and On-X mechanical valves. Methods: We included 99 patients who underwent aortic valve replacement with mechanical valves between 2017 and 2019. Three types of mechanical valves were used, On-X valve (n=45), ATS AP360 (n=32), and Bicarbon (n=22). The mean prosthetic valve gradient was measured postoperatively and after six months. Results: Preoperative data were comparable between groups, and there were no differences in preoperative echocardiographic data. Pre-discharge echocardiography showed no difference between groups in the ejection fraction (P=0.748), end-systolic (P=0.764) and end-diastolic (P=0.723) diameters, left ventricular mass index (P=0.348), aortic prosthetic mean pressure gradient (P=0.454), and indexed aortic prosthetic orifice area (P=0.576). There was no difference in the postoperative aortic prosthetic mean pressure gradient between groups when stratified by valve size. The changes in the aortic prosthetic mean pressure gradient of the intraoperative period, at pre-discharge, and at six months were comparable between the three prostheses (P=0.08). Multivariable regression analysis revealed that female gender (beta coefficient -0.242, P=0.027), body surface area (beta coefficient 0.334, P<0.001), and aortic prosthetic size (beta coefficient -0.547, P<0.001), but not the prosthesis type, were independent predictors of postoperative aortic prosthetic mean pressure gradient. Conclusion: The three bileaflet mechanical aortic prostheses (On-X, Bicarbon, and ATS) provide satisfactory early hemodynamics, which are comparable between the three valve types and among different valve sizes.


Asunto(s)
Humanos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Diseño de Prótesis , Ecocardiografía , Ecocardiografía Doppler , Hemodinámica
14.
Ann Thorac Surg ; 112(5): 1493-1500, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33242434

RESUMEN

BACKGROUND: The ideal tricuspid valve annuloplasty (TVA) prosthesis is controversial. This study aimed to compare the effect of rigid versus flexible TVA prostheses on long-term outcomes after repair of functional tricuspid regurgitation (FTR). METHODS: We included 713 patients who had repair of FTR from 2009 to 2017. Patients were divided into 2 groups according to the type of TVA prosthesis. Group 1 (n = 104) included patients who had repair using rigid rings; group 2 (n = 609) included patients with flexible bands. Median age was 53.5 years (25th through 75th percentiles; range, 42.5-62 years) in group 1 versus 56 years (range, 45-65 years) in group 2 (P = .11). Propensity score matching identified 91 matched pairs for comparison. RESULTS: In the matched pairs, operative mortality was identical (4 in both groups [4.4%]; P ˃ .99). Median follow-up was 55 months (range, 28-83 months). The cumulative incidence of moderate or higher tricuspid regurgitation (TR) in the presence of death as a competing risk was higher in group 2 (subdistribution hazard ratio = 1.63, P = .019; and subdistribution hazard ratio = 1.6, P = .099 before and after matching, respectively). There was a trend of higher pacemaker insertion in group 1 (7 [7.69%] versus 3 [3.3%]; P = .34), which did not reach statistical significance after matching. There was no significant change in the degree of TR over time between groups (odds ratio = 1.21, P = .53; and odds ratio = 1.75, P = .21 before and after matching, respectively). CONCLUSIONS: Both types of TVA prostheses had comparable efficacy in managing FTR; however, freedom from moderate or more TR was higher in the rigid ring group.


Asunto(s)
Anuloplastia de la Válvula Cardíaca , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide/cirugía , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
15.
Braz J Cardiovasc Surg ; 36(1): 10-17, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33355803

RESUMEN

INTRODUCTION: There are scarce data comparing different mechanical valves in the aortic position. The objective of this study was to compare the early hemodynamic changes after aortic valve replacement between ATS, Bicarbon, and On-X mechanical valves. METHODS: We included 99 patients who underwent aortic valve replacement with mechanical valves between 2017 and 2019. Three types of mechanical valves were used, On-X valve (n=45), ATS AP360 (n=32), and Bicarbon (n=22). The mean prosthetic valve gradient was measured postoperatively and after six months. RESULTS: Preoperative data were comparable between groups, and there were no differences in preoperative echocardiographic data. Pre-discharge echocardiography showed no difference between groups in the ejection fraction (P=0.748), end-systolic (P=0.764) and end-diastolic (P=0.723) diameters, left ventricular mass index (P=0.348), aortic prosthetic mean pressure gradient (P=0.454), and indexed aortic prosthetic orifice area (P=0.576). There was no difference in the postoperative aortic prosthetic mean pressure gradient between groups when stratified by valve size. The changes in the aortic prosthetic mean pressure gradient of the intraoperative period, at pre-discharge, and at six months were comparable between the three prostheses (P=0.08). Multivariable regression analysis revealed that female gender (beta coefficient -0.242, P=0.027), body surface area (beta coefficient 0.334, P<0.001), and aortic prosthetic size (beta coefficient -0.547, P<0.001), but not the prosthesis type, were independent predictors of postoperative aortic prosthetic mean pressure gradient. CONCLUSION: The three bileaflet mechanical aortic prostheses (On-X, Bicarbon, and ATS) provide satisfactory early hemodynamics, which are comparable between the three valve types and among different valve sizes.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Ecocardiografía Doppler , Femenino , Hemodinámica , Humanos , Masculino , Diseño de Prótesis
16.
J Saudi Heart Assoc ; 32(2): 213-218, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33154919

RESUMEN

BACKGROUND: Tricuspid valve regurgitation may affect the outcomes after heart transplantation. There is a paucity of data reporting the outcomes of heart transplants in our region. The objectives of this study were to report the occurrence of tricuspid regurgitation after heart transplantation, its course, and its effect on survival. METHODS: From 2009 to 2019, 30 patients had heart transplantation at our cardiac center. Their age was 36.73 ± 13.5 years, and 25 (83.33%) were males. Indications for transplantation were dilated cardiomyopathy (n = 21; 72.41%), ischemic cardiomyopathy (n = 8; 26.67%) and hypertrophic cardiomyopathy (n = 1; 3.45%). Cardiopulmonary bypass time was 157.24 ± 34.6 min, and ischemic time was 138 ± 73.56 min. All patients had orthotopic heart transplantation with a bi-caval technique. RESULTS: Eleven patients had severe tricuspid regurgitation postoperatively (37%). The degree of tricuspid regurgitation decreased significantly after 6 months (p = 0.011) and remained stationary during the follow-up. Pre-transplant dilated cardiomyopathy was significantly associated with severe tricuspid regurgitation post-transplant (p = 0.017). The mean follow-up was 39.43 ± 50.57 months. Survival at 10 years was 90% in patients with less than moderate tricuspid regurgitation postoperatively compared to 43% for patients with moderate and severe tricuspid regurgitation (log-rank p = 0.0498). CONCLUSION: Tricuspid regurgitation is a common problem after heart transplantation. Despite the improvement of the degree of tricuspid regurgitation after 6 months, survival was negatively affected by postoperative moderate or severe tricuspid regurgitation. Patients with dilated cardiomyopathy may benefit from concomitant tricuspid valve repair at the time of heart transplantation. Further larger studies are warranted.

18.
J Card Surg ; 35(12): 3362-3367, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32996198

RESUMEN

BACKGROUND: Reintervention after transcatheter edge to edge repair using MitraClip is still challenging. We aimed to report our experience in reinterventions after MitraClip procedures and describe the outcomes. METHODS: From 2012 to 2020, 167 patients had a transcatheter edge to edge repair; 10 of them needed reinterventions. At the time of the first MitraClip, the median EuroSCORE was 4.29 (2.62-7.52), and the ejection fraction was 30 (20-40)%. RESULTS: Emergency mitral valve replacement (MVR) was performed in two patients, elective MVR in three, cardiac transplantation in two, and repeat clipping in threepatients. The median time from MitraClip to the reintervention was 4.5 (2-13) months. One patient required extracorporeal membrane oxygenation support after elective MVR. Repeat clipping failed to control mitral regurgitation grade in all patients. Clip detachment was reported in five patients (50%). The median follow-up after the reintervention was 19.5 (9-75) months, and mortality occurred in two patients who had repeat clipping (20%). CONCLUSIONS: MVR after MitraClip is feasible with low morbidity and mortality. Repeat mitral valve clipping had a high failure rate. Mitral repair was not feasible in all patients in our series, and the use of MitraClip to delay surgical interventions may not be feasible if mitral repair is an option.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
19.
Heart Lung Circ ; 29(9): 1405-1411, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32360029

RESUMEN

BACKGROUND: Paediatric del Nido cardioplegia (DNC) has been tested in selected populations of low-risk adult patients. This study examined its use in an unselected medium-to-high-risk adult population and compared the results with a propensity-matched population that received intermittent warm blood cardioplegia (IWBC). METHODS: Data from the last 1,000 consecutive adult patients who underwent a variety of surgical procedures under cardioplegic arrest with the use of IWBC or DNC between 2016 and 2018 were propensity score matched on preoperative clinical and demographic variables. Two (2) main populations were 102 patients who received DNC and another set of matched 102 patients from a total of 1,000 patients who received IWBC, along with a subgroup with an ejection fraction (EF) ≤40% (EFDNC vs EFIWBC). Postoperative outcomes were mortality, peak troponin T, postoperative EF%, and aortic cross-clamp time. RESULTS: There were no preoperative differences amongst the groups in the main cohort (Euroscore II: DNC 4.1±8, IWBC 4.0±7; EF%: DNC 47±10, IWBC 47±11) and in the subgroup (EF%: EFDNC 32±6%, EFIWBC 32±6%; p=0.45). There were also no differences in three of the outcomes. A significant postoperative improvement was noticed in the EF% in the DNC (32±6% 95% CI 29-34 to 39±12 95% CI 34-44; p=0.001) in the EFDNC group. CONCLUSIONS: This initial experience of del Nido cardioplegia proved to be effective in a variety of challenging pathologies in adult populations.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Paro Cardíaco Inducido/métodos , Cardiopatías/terapia , Puntaje de Propensión , Adulto , Femenino , Cardiopatías/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
20.
J Infect Public Health ; 13(5): 821-823, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32241725

RESUMEN

Q fever prosthetic valve endocarditis in association with antiphospholipid antibody syndrome (APS) in systemic lupus erythematosus (SLE) has not been previously reported. Here, we report a 22-year-old Saudi female diagnosed with SLE and APS. She had mitral valve replacement with bio-prosthesis five years earlier for Libman-Sack endocarditis. She presented with two months' history of fever, cough, palpitations, and progressive shortness of breath. A transthoracic echocardiogram showed a degenerative mitral valve prosthesis with a large mass causing severe obstruction. Open heart surgery revealed multiple masses on the mitral valve. PCR from the resected tissues was positive for Coxiella burnetii DNA. Q fever serology showed phase two IgG 1:2048, phase one IgG 1:512, and IgM 1:1024. The valve was replaced with a bio-prosthesis. She was well at 12 months of follow-up.


Asunto(s)
Síndrome Antifosfolípido/complicaciones , Bioprótesis/efectos adversos , Endocarditis Bacteriana/diagnóstico , Prótesis Valvulares Cardíacas/efectos adversos , Lupus Eritematoso Sistémico/complicaciones , Fiebre Q/diagnóstico , Procedimientos Quirúrgicos Cardíacos , Coxiella burnetii/aislamiento & purificación , ADN Bacteriano/aislamiento & purificación , Ecocardiografía , Endocarditis Bacteriana/cirugía , Femenino , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/patología , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/cirugía , Reacción en Cadena de la Polimerasa , Fiebre Q/cirugía , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...